--> Coil Cords
Call us Now (800) 967-9147

Coiled Cords


Click Here for a Custom Cord/Cable Design Quote.

  • Superior Coil Memory
  • Outdoor & Indoors
  • UL, CSA, Mil Spec Standards

Custom Lengths, jacket colors and conductors colors can be specified using the Custom Cable Form.

Unshielded Six Inch Leads on Each End

Custom Colors Available Upon Request

coil cable, custom electrical cable

Product Specification

LENGTH CODES: Suffix: - Add to part number.
Example (Part E-282 + Suffix 5 = E-2825)
5 5 - 5 Ft. Working Length (12 In. approx. retracted length)
10 10- 10 Ft. Working Length (24 In. approx. retracted length)
15 15- 15 Ft. Working Length (36 In. approx. retracted length)
20 20- 20 Ft. Working Length (48 In. approx. retracted length)
Cond. Colors Per UL & CSA guidelines.
coil cable specifications


28 Gauge Soft Annealed Tinned Copper - Maximum Voltage: 300 Volts

Part No Working
Lengths
Feet
Copper
Stranding
Number of
Conductors
Nom.
Cable O.D
(Inches)
Nom.
Coil O.D
(Inches)
Amp
Rating
E-282 5,10,15,20 7 X 36 2 .130 .500 3
E-283 5,10,15,20 7 X 36 3 .145 .525 3
E-284 5,10,15,20 7 X 36 4 .155 .550 3
E-285 5,10,15,20 7 X 36 5 .175 .620 3
E-286 5,10,15,20 7 X 36 6 .185 .700 2
E-287 5,10,15,20 7 X 36 7 .185 .700 2
E-2810 5,10,15,20 7 X 36 10 .225 .790 2
E-2815 5,10,15,20 7 X 36 15 .260 .950 2
E-2825 5,10,15,20 7 X 36 25 .315 1.07 2
E-2840 5,10,15,20 7 X 36 40 .370 1.28 1


26 Gauge Soft Annealed Tinned Copper - Maximum Voltage: 300 Volts

Part No Length
Feet
Copper
Stranding
Number of
Conductors
Nom.
Cable O.D
(Inches)
Nom.
Coil O.D
(Inches)
Amp
Rating
E-262 5,10,15,20 7 X 34 2 .145 .530 4
E-263 5,10,15,20 7 X 34 3 .155 .550 4
E-264 5,10,15,20 7 X 34 4 .175 .620 4
E-265 5,10,15,20 7 X 34 5 .185 .710 4
E-266 5,10,15,20 7 X 34 6 .205 .750 3
E-267 5,10,15,20 7 X 34 7 .205 .750 3
E-2610 5,10,15,20 7 X 34 10 .255 .940 3
E-2615 5,10,15,20 7 X 34 15 .290 1.00 3
E-2625 5,10,15,20 7 X 34 25 .350 1.24 2
E-2640 5,10,15,20 7 X 34 40 .410 1.57 1


24 Gauge Soft Annealed Tinned Copper- Maximum Voltage: 300 Volts

Part No Length
Feet
Copper
Stranding
Number of
Conductors
Nom.
Cable O.D
(Inches)
Nom.
Coil O.D
(Inches)
Amp
Rating
E-242 5,10,15,20 19 X 36 2 .155 .550 3
E-243 5,10,15,20 19 X 36 3 .175 .620 3
E-244 5,10,15,20 19 X 36 4 .185 .700 3
E-245 5,10,15,20 19 X 36 5 .210 .780 3
E-246 5,10,15,20 19 X 36 6 .230 .800 2
E-247 5,10,15,20 19 X 36 7 .230 .800 2
E-2410 5,10,15,20 19 X 36 10 .285 .990 2
E-2415 5,10,15,20 19 X 36 15 .325 1.190 2
E-2425 5,10,15,20 19 X 36 25 .390 1.530 2
E-2440 5,10,15,20 19 X 36 40 .455 1.660 1


22 Gauge Soft Annealed Tinned Copper- Maximum Voltage: 300 Volts

Part No Length
Feet
Copper
Stranding
Number of
Conductors
Nom.
Cable O.D
(Inches)
Nom.
Coil O.D
(Inches)
Amp
Rating
E-222 5,10,15,20 19 X 34 2 .180 .690 4
E-223 5,10,15,20 19 X 34 3 .200 .740 4
E-224 5,10,15,20 19 X 34 4 .210 .760 4
E-225 5,10,15,20 19 X 34 5 .235 .810 4
E-226 5,10,15,20 19 X 34 6 .250 .928 3
E-227 5,10,15,20 19 X 34 7 .250 .928 3
E-2210 5,10,15,20 19 X 34 10 .320 1.18 3
E-2215 5,10,15,20 19 X 34 15 .355 1.25 3
E-2225 5,10,15,20 19 X 34 25 .440 1.63 2
E-2240 5,10,15,20 19 X 34 40 .515 1.78 1