Cable Options
Product Information
Philaflex™ Mil DTL 3432 Extra Heavy Duty Class HE 600 Volts
Click Here for a Custom Cord/Cable Design Quote.
Features:
Ultimate Flexibility, fire retardant, long life, greater mechanical strength, lighter weight, and resistance to low temperatures,
heat aging, abrasion, chemicals, oil, ozone, and water.
Applications:
Extra heavy duty service for outdoors or indoors power generation and control.
Standards:
MIL-DTL-3432J
Temperature:
Temperature rating is from -65°C to +105°C. (Exceeds best Class E of MIL-DTL-3432H which is -65°C to + 90°C.)
Branding:
Per MIL-STD-686
Jacket Color:
Black. Other colors available upon request.
Cond. Colors:
2/C – black & white; 3/C black, white & green, 4/C – black, white, red & green; 5/C – black, white, red, green, and orange.
Part Number | AWG Size | No.of Cond | Type Designation | Nom. O.D. (inches) | Approx. Lbs. M/ft |
P02-HEF(2/18)-0404 | 18 | 2 | CO-02HEF(2/18)0404 | 0.404 | 65 |
P03-HEF(3/18)-0422 | 18 | 3 | CO-03HEF(3-18)0422 | 0.422 | 78 |
P04-HEF(4/18)-0485 | 18 | 4 | CO-04HEF(4/18)0485 | 0.485 | 105 |
P02-HEF(2/16)-0428 | 16 | 2 | CO-02HEF(2/16)0428 | 0.428 | 76 |
P03-HEF(3/16)-0448 | 16 | 3 | CO-03HEF(3/16)0448 | 0.448 | 93 |
P04-HEF(4/16)-0514 | 16 | 4 | CO-04HEF(4/16)0514 | 0.514 | 125 |
P02-HEF(2/14)-0547 | 14 | 2 | CO-02HEF(2/14)0547 | 0.547 | 119 |
P03-HEF(3/14)-0573 | 14 | 3 | CO-03HEF(3/14)0573 | 0.573 | 146 |
P04-HEF(4/14)-0618 | 14 | 4 | CO-04HEF(4/14)0618 | 0.618 | 177 |
P02-HEF(2/12)-0585 | 12 | 2 | CO-02HEF(2/12)0585 | 0.585 | 143 |
P03-HEF(3/12)-0614 | 12 | 3 | CO-03HEF(3/12)0614 | 0.614 | 180 |
P04-HEF(4/12)-0664 | 12 | 4 | CO-04HEF(4/12)0664 | 0.664 | 221 |
P02-HEF(2/10)-0634 | 10 | 2 | CO-02HEF(2/10)0634 | 0.634 | 179 |
P03-HEF(3/10)-0667 | 10 | 3 | CO-03HEF(3/10)0667 | 0.667 | 231 |
P04-HEF(4/10)-0723 | 10 | 4 | CO-04HEF(4/10)0723 | 0.723 | 287 |
P02-HEF(2/8)-0634 | 8 | 2 | CO-02HEF(2/8)0634 | 0.812 | 280 |
P03-HEF(3/8)-0667 | 8 | 3 | CO-03HEF(3/8)0667 | 0.586 | 364 |
P04-HEF(4/8)-0723 | 8 | 4 | CO-04HEF(4/8)0723 | 0.965 | 480 |
P05-HEF(5/8)-1086 | 8 | 5 | CO-05HEF(5/8)1086 | 1.086 | 602 |
Part Number | AWG Size | No. of Cond. | Ground | Type Designation | Nom. O.D. (Inches) | Approx. Lbs. M/ft |
P02-HEF(2/6)-0936 | 6 | 2 | 0 | CO-02HEF(2/6)-0936 | 0.936 | 392 |
P03-HEF(3/6)-0986 | 6 | 3 | 0 | CO-03HEF(3/6)-0986 | 0.986 | 515 |
P03-HEF(3/6-3/10R)-1010 | 6 | 3 | 3 #10 gauge | CO-03HEF(3/6-3/10R)-1010 | 0.101 | 625 |
P04-HEF(4/6)-1106 | 6 | 4 | 0 | CO-04HEF(4/6)-1106 | 1.106 | 674 |
P05-HEF(5/6)-1227 | 6 | 5 | 0 | CO-05HEF(5/6)-1227 | 1.227 | 838 |
P02-HEF(2/4)-1106 | 4 | 2 | 0 | CO-02HEF(2/4)-1106 | 1.106 | 562 |
P02-HEF(2/4-2/8R)-1100 | 4 | 2 | 2 #8 gauge | CO-02HEF(2/4-2/8R)-1100 | 1.1 | 625 |
P03-HEF(3/4)-1197 | 4 | 3 | 0 | CO-03HEF(3/4)-1197 | 1.197 | 778 |
P04-HEF(4/4)-1302 | 4 | 4 | 0 | CO-04HEF(4/4)-1302 | 1.302 | 976 |
P04-HEF(4/4-4/12R)-1290 | 4 | 4 | 4 #12 gauge | CO-04HEF(4/4-4/12R)-1290 | 1.29 | 1080 |
P04-HEF(4/4-4/10R)-1290 | 4 | 4 | 4 #10 gauge | CO-04HEF(4/4-4/10R)-1290 | 1.29 | 1096 |
P05-HEF(5/4)-1458 | 4 | 5 | 0 | CO-05HEF(5/4)-1458 | 1.458 | 1190 |
P02-HEF(2/2)-1386 | 2 | 2 | 0 | CO-02HEF(2/2)-1386 | 1.386 | 809 |
P03-HEF(3/2)-1498 | 2 | 3 | 0 | CO-03HEF(3/2)-1498 | 1.498 | 1087 |
P04-HEF(4/2)-1635 | 2 | 4 | 0 | CO-04HEF(4/2)-1635 | 1.653 | 1411 |
P04-HEF(4/2-4/8R)-1435 | 2 | 4 | 4 #8 gauge | CO-04HEF(4/2-4/8R)-1435 | 1.435 | 1550 |
P05-HEF(5/2)-1829 | 2 | 5 | 0 | CO-05HEF(5/2)-1829 | 1.829 | 1711 |
P04-HEF(4/1-4/8R)1620 | 1 | 4 | 4 #8 gauge | CO-04HEF(4/1-4/8R)1620 | 1.62 | 2195 |
P04-HEF(4/4/0-4/4R)2380 | 4/0 | 4 | 4 #4 gauge | CO-04HEF(4/4/0-4/4R)2380 | 2.38 | 4994 |